Home / High Voltage Tester Rental

High voltage tester rental

At IONIO you rent a hipot tester from 6 to 80 kV, AC or DC, by the week. The tester is supplied calibrated, with a calibration certificate.

Nefit logo, IONIO customer
Lixerio logo, IONIO customer
Modular Lighting Instruments logo, IONIO customer
Quooker logo, IONIO customer
Deltalight logo, IONIO customer
Bos Nieuwkoop logo, IONIO customer
PITT cooking logo, IONIO customer
Novy logo, IONIO customer
TVH logo, IONIO customer

Which high voltage tester do you need?

That depends on your test object and the standard. For production and final testing of appliances, 6 kV is enough. A type test or a test above 6 kV is done with the GLP1-g up to 40 kV AC. Cables, motors and generators are tested on site with the HV-DC up to 80 kV.

GLP2-Basic 1930 safety tester with hipot up to 6 kV

GLP2-Basic 1930

Up to 6 kV AC and DC

Complete safety test for production and certification.

  • AC max. 100 mA, DC max. 4 mA
  • Earth bond, insulation, leakage current and function test
  • With connection box
GLP1-e AC high voltage tester 6 kV

GLP1-e AC

Up to 6 kV AC

Breakdown test with two high voltage pistols and a warning lamp.

  • 0 to 6,000 V, max. 100 mA
  • Burn function for fault location
  • Interlock and emergency stop (EN 50191)
GLP1-g AC high voltage tester 40 kV with transformer

GLP1-g AC 40 kV

Up to 40 kV AC

For a type test or a one-off inspection above 6 kV.

  • 300 to 40,000 V, 50 Hz
  • Leakage current measurement 0.1 to 15 mA
  • Store programs, control via PC
HV-DC 80 kV mobile high voltage tester

HV-DC 80 kV

Up to 80 kV DC

On-site insulation testing of cables, motors, generators and transformers.

  • 2 to 80 kV DC (negative), max. 10 mA
  • Emergency stop and safety LED for residual voltage
  • Two modules, approx. 17 kg in total

Not sure which one fits? Put your test object and the required test voltage in your request. Would you rather buy? Take a look at our high voltage testers.

Working on HV components in substations?

Commissioning or overhauling transformers, circuit breakers and protection also means measuring turns ratio, contact resistance and insulation resistance. For that work you can also rent these four testers from IONIO.

TRAN-203 transformer analyser

TRAN-203

Transformers

Turns ratio, winding resistance and demagnetisation with one cable set.

  • Ratio 0.8 to 50,000, accuracy 0.08 %
  • Winding resistance up to 20 A DC, primary and secondary without reconnecting
  • Tap changer (OLTC) and automatic vector group detection
SUWI-120 multifunction substation tester with touchscreen

SUWI-120

Breakers, relays and instrument transformers

Four substation tests in one 10.7 kg case.

  • Relay timing up to 110 A AC / 120 A DC
  • Contact resistance up to 120 A DC, resolution 0.01 µΩ
  • Turns ratio 0.8 to 10,000 and 3-phase breaker timing
Megabras MD15KVR insulation resistance tester 15 kV

MD-15KVR

Insulation resistance up to 15 kV DC

Battery-powered insulation tester for PI and DAR measurements on transformers, motors and medium voltage cables.

  • 500 V to 15 kV DC, up to 15 TΩ
  • PI, DAR, step voltage and ramp
  • IP65, 6.3 kg, with printer
MPK105R 100 A micro-ohmmeter in portable case

MPK105R

Micro-ohmmeter up to 100 A

Measures the contact resistance of circuit breakers, busbar joints and disconnectors, for example during a maintenance shutdown.

  • Test current 5 to 100 A DC
  • Resolution 0.1 µΩ, range up to 300 mΩ
  • 4-wire measurement, approx. 11 kg

They are supplied calibrated, with a complete cable set. The TRAN-203 and SUWI-120 also come with DMP software.

HighTest VABO-80 vacuum bottle tester up to 80 kV in its case

When do you rent a high voltage tester?

You often only need a high voltage tester for a few weeks: for a handover, a type test or a batch that has to be tested. You rent it for that period and then it goes back. That way no expensive tester sits in a cupboard between jobs.

Renting also works when your own tester is away for calibration or repair. IONIO supplies, calibrates and maintains these testers itself.

GLP1-g high voltage tester with HV transformer behind a screened test area with warning sign

Working safely with high voltage

Working with high voltage falls under EN 50191. You need instructed people and a shielded test area. The GLP1-e has an interlock and an emergency stop, the HV-DC 80 kV has an emergency stop and a safety LED that shows whether the test object is still live. Discharge and earth the test object after the test.

Would you like instruction on delivery? Mention it in your request and we will include it in the quotation.

Rental request

Choose the tester or describe your test object and the test voltage. You will usually receive a quotation with price and availability within 24 hours. The minimum rental period is 1 week, and you can extend.

Prefer to call? +31 85 401 60 45, or WhatsApp +31 6 137 459 95. You can also email info@ionio.nl.

Answers to your questions

Are the testers calibrated on delivery?

Can training also be provided when renting the tester?

Is there also the possibility of support during the measurements?

What is the minimum and maximum rental term?

Can we take over rental test systems?

How can I connect my test object to the rental systems?