The GLP2-BT is the test system for testing high-voltage batteries in electric vehicles.
High-voltage batteries are used in a variety of applications, such as electric vehicles, energy storage systems, and industrial machinery.
During production of the high-voltage batteries, we check the insulation resistance and breakdown resistance of the batteries. The batteries can consist of single cells or complete battery packs
Test methods
Insulation resistance up to 1000VDC in 4-wire technique.
High-voltage DC test up to 3.5 kV and 1 mA/3 mA potential-free in 4-wire technique.
Test connections
10-pin HAN-ECO Harting plug at rear. 2 Pole terminals 4 mm for insulation resistance. 2 HV sockets for HVDC. Standard external control protocol is SCPI.
Insulation resistance 50 – 1000 V, Riso > 5 GΩ
HVDC 50 – 3500 V, max. 3 mA, potential-free safety current limited. Limit-dependent fast shutdown of HVDC current. Contact check ISO and HVDC in automatic mode. Visual check.
Mathematical calculation. Manual measurement.
Interfaces
Digital I/O.
LAN (SCPI). RS232 (for external matrix boxes). CAN bus (for external matrix boxes). USB. HDMI. Industrial bus systems (optional)
Gijsbert at IONIO is here to help you.
At IONIO, we not only supply advanced testing and measurement systems, but also offer clear and expert advice to optimise the testing of your product.
Find out how we can improve your business processes. A consultation can be scheduled in no time!
Also collaborate on technical challenges?
Then you have come to the right place at IONIO!